15:17:09 acc-brn-1 %LINK-3-UPDOWN: Interface GigabitEthernet1/0/12, changed state to up 15:16:52 core-brn-1 %SMART_LIC-3-COMM_FAILED: Communications failure with the Cisco Smart License Utility (CSLU) : Unable to resolve server hostname/domain name 15:15:38 rtr-lug-1 %CELLWAN-2-NC_EVENT: Cellular0/2/0: Network change event, Radio Access Technology: LTE, Band: 3, RSRP: -97 dBm 14:57:00 INC-1009 opened: Bern: WiFi slow in one area (P3) 14:53:00 INC-1008 opened: Lugano: network alarm, no user impact so far (P3) 14:49:01 INC-1006 expired: SLA breached 14:43:00 INC-1007 expired: SLA breached 14:25:00 INC-1007 opened: Bern: network almost unusable (P2) 14:24:00 INC-1005 expired: SLA breached 14:01:00 INC-1006 opened: Bern: hardware alarm, no user impact (P4) 14:00:01 INC-1004 expired: SLA breached 13:47:01 INC-1005 opened: Bern: network alarm, no user impact so far (P3)

Incidents

The shared ticket inbox of the NOC shift.

P4 INC-1006 · Medium · reported by Samuel Rey (Monitoring)

Bern: hardware alarm, no user impact

SLA breached
  1. Samuel Rey (Monitoring) Report 14:01:00

    One of the Bern devices raised an environment alarm at 14:01. No impact visible so far. Can the NOC take a look?

  2. NOC-POC System 14:49:01

    SLA breached: nobody solved this incident in time. The fault was repaired.

Post-mortem

Root cause
A power supply of core-brn-2 failed; the second one carried the load.
Fault
PSU failure
Right answer
D: Replace the failed power supply of core-brn-2
Solved by
Nobody: SLA breached

PS2 of core-brn-2 failed at 14:01:00; the remaining supply carries the load.

  1. A power supply of core-brn-2 failed; the second one carried the load.
  2. What was noticed: a hardware alarm while the device kept running.
  • Replace the failed power supply of core-brn-1 Wrong: it assumed a power supply of core-brn-1 had failed. core-brn-1 was healthy: no alarm, its sensors and power supplies were normal. The cause: A power supply of core-brn-2 failed; the second one carried the load.
  • Roll back the last configuration change on core-brn-1 Wrong: it assumed a configuration change on core-brn-1 broke it. core-brn-1 was healthy: no alarm, its sensors and power supplies were normal. The cause: A power supply of core-brn-2 failed; the second one carried the load.
  • Roll back the last configuration change on core-brn-2 Wrong: it assumed a configuration change on core-brn-2 broke it. Right place, wrong fault: core-brn-2 had no such problem. The cause: A power supply of core-brn-2 failed; the second one carried the load.
  1. 14:01:00 INC-1006 opened: Bern: hardware alarm, no user impact (Samuel Rey (Monitoring))
  2. 14:49:01 SLA breached; fault repaired